EPA drinking water standards table: every MCL, MCLG, action level and secondary standard a home water test reports against

Lead 15 ug/L action level, nitrate 10 mg/L, arsenic 0.010 mg/L, PFOA and PFOS 4.0 ppt, TDS 500 mg/L secondary: every EPA MCL and secondary standard, one table.

  • Verified
  • Updated
  • 10 min read
  • 5 sources
A printed water test report and a handheld TDS meter on the counter of a bright kitchen, with a glass of tap water and an under-sink filter housing visible below

Shop links on this page are affiliate links: a purchase may earn us a commission at no extra cost to you. Disclosure

Short answer

EPA’s National Primary Drinking Water Regulations (NPDWR) set an enforceable Maximum Contaminant Level (MCL) for 16 inorganic chemicals, 53 organic chemicals, 4 disinfection byproducts and 4 radionuclide categories, all listed below in mg/L. The figures a home test panel is measured against most often: arsenic 0.010 mg/L, nitrate 10 mg/L as nitrogen, fluoride 4.0 mg/L, a copper action level of 1.3 mg/L and a lead action level of 0.015 mg/L, which EPA’s NPDWR page says drops to 0.010 mg/L on the Lead and Copper Rule Improvements compliance date of November 1, 2027. EPA’s 2024 PFAS rule adds an MCL of 4.0 parts per trillion each for PFOA and PFOS, with compliance due April 2029; EPA has proposed moving that date to April 2031 and rescinding the limits on four other PFAS, and neither proposal showed as final on EPA’s pages on November 3, 2026. The 15 secondary standards, such as iron 0.3 mg/L and TDS 500 mg/L, are non-mandatory taste and staining guides, not legal limits.

If your lab report already prints an “EPA limit” column beside every result, you can leave now: these are the same numbers, and all this page adds is which of them are enforceable.

Which limits are looked up most?

The ten lines a home report is checked against most often, copied from EPA’s pages on November 3, 2026.

ContaminantEPA limitTypeGroup
Lead0.015 mg/L (15 µg/L), 0.010 mg/L from November 1, 2027Action level, enforceableInorganic
Copper1.3 mg/LAction level, enforceableInorganic
Arsenic0.010 mg/LMCL, enforceableInorganic
Nitrate (as N)10 mg/LMCL, enforceableInorganic
Fluoride4.0 mg/L (2.0 mg/L secondary)MCL, enforceableInorganic
PFOA and PFOS4.0 ppt eachMCL, enforceablePFAS
Total coliformsNo more than 5.0% of monthly samples positiveMCL, enforceableMicrobial
Chlorine (as Cl2)4.0 mg/LMRDL, enforceableDisinfectants
Iron0.3 mg/LSecondary, non-mandatorySecondary
Total dissolved solids (TDS)500 mg/LSecondary, non-mandatorySecondary

Jump to a group: inorganic chemicals, organic chemicals, microorganisms, disinfectants and byproducts, radionuclides, PFAS, lead action level, secondary standards.

Which limits are enforceable and which are not?

A Maximum Contaminant Level (MCL) is the highest concentration EPA allows from a public water system, and it is enforceable. A Maximum Contaminant Level Goal (MCLG) is the non-enforceable health target, which is why an MCLG can be zero while the MCL is not.

A Treatment Technique (TT) replaces an MCL where sampling every tap is impractical; lead and copper use one, with an action level at the 90th percentile of sampled taps. A Maximum Residual Disinfectant Level (MRDL) caps a disinfectant the system adds on purpose. A secondary standard is one of 15 non-mandatory levels set for taste, color and odor.

Every EPA limit applies to public water systems, none to a private well; the well water test panel guide covers which results to order.

What are the EPA MCLs for inorganic chemicals?

Values from EPA’s NPDWR page, in mg/L, the same as parts per million (ppm).

ContaminantMCLG (mg/L)MCL (mg/L)OwnerSpec guide
Antimony0.0060.006none
Arsenic00.010arsenic in well water
Asbestos7 million fibers/L (over 10 µm)7 million fibers/Lnone
Barium22none
Beryllium0.0040.004none
Cadmium0.0050.005none
Chromium (total)0.10.1none
Copper1.3TT; action level 1.3blue-green stains and low pH
Cyanide (free)0.20.2none
Fluoride4.04.0fluoride in tap water
LeadzeroTT; action level 0.015 (0.010 from November 1, 2027)lead in tap water
Mercury (inorganic)0.0020.002none
Nitrate (as N)1010nitrate in well water
Nitrite (as N)11none
Selenium0.050.05none
Thallium0.00050.002none

Nitrate and nitrite are stated as nitrogen. A lab reporting “nitrate as NO3” uses a different scale; the nitrate guide shows the conversion.

What are the EPA MCLs for organic chemicals?

EPA’s NPDWR page lists 53 organic chemicals apart from PFAS, mostly solvents and pesticides; acrylamide and epichlorohydrin are treatment techniques on the dose a system may add. Values in mg/L.

ContaminantMCLG (mg/L)MCL (mg/L)
AcrylamidezeroTT (0.05% dosed at 1 mg/L)
Alachlorzero0.002
Atrazine0.0030.003
Benzenezero0.005
Benzo(a)pyrene (PAHs)zero0.0002
Carbofuran0.040.04
Carbon tetrachloridezero0.005
Chlordanezero0.002
Chlorobenzene0.10.1
2,4-D0.070.07
Dalapon0.20.2
1,2-Dibromo-3-chloropropane (DBCP)zero0.0002
o-Dichlorobenzene0.60.6
p-Dichlorobenzene0.0750.075
1,2-Dichloroethanezero0.005
1,1-Dichloroethylene0.0070.007
cis-1,2-Dichloroethylene0.070.07
trans-1,2-Dichloroethylene0.10.1
Dichloromethanezero0.005
1,2-Dichloropropanezero0.005
Di(2-ethylhexyl) adipate0.40.4
Di(2-ethylhexyl) phthalatezero0.006
Dinoseb0.0070.007
Dioxin (2,3,7,8-TCDD)zero0.00000003
Diquat0.020.02
Endothall0.10.1
Endrin0.0020.002
EpichlorohydrinzeroTT (0.01% dosed at 20 mg/L)
Ethylbenzene0.70.7
Ethylene dibromidezero0.00005
Glyphosate0.70.7
Heptachlorzero0.0004
Heptachlor epoxidezero0.0002
Hexachlorobenzenezero0.001
Hexachlorocyclopentadiene0.050.05
Lindane0.00020.0002
Methoxychlor0.040.04
Oxamyl (Vydate)0.20.2
Polychlorinated biphenyls (PCBs)zero0.0005
Pentachlorophenolzero0.001
Picloram0.50.5
Simazine0.0040.004
Styrene0.10.1
Tetrachloroethylenezero0.005
Toluene11
Toxaphenezero0.003
2,4,5-TP (Silvex)0.050.05
1,2,4-Trichlorobenzene0.070.07
1,1,1-Trichloroethane0.200.2
1,1,2-Trichloroethane0.0030.005
Trichloroethylenezero0.005
Vinyl chloridezero0.002
Xylenes (total)1010

A home panel rarely runs this group; it is ordered when a well sits near farmland, a fuel tank or industry.

What are the EPA limits for microorganisms?

Most microbial limits are treatment techniques on the public system. The one a home test returns is total coliforms, which EPA sets as a monthly sample percentage.

ContaminantMCLGMCL or TT
CryptosporidiumzeroTT (watershed control for unfiltered systems)
Giardia lambliazeroTT (99.9% removal or inactivation)
Heterotrophic plate count (HPC)n/aTT (no more than 500 colonies per mL)
LegionellazeroTT (no limit; controlled by Giardia and virus treatment)
Total coliforms (including fecal coliform and E. coli)zeroNo more than 5.0% of samples positive in a month; one sample for systems taking fewer than 40 a month
Turbidityn/aTT (never above 1 NTU; 0.3 NTU or less in 95% of monthly samples, conventional or direct filtration)
Viruses (enteric)zeroTT (99.99% removal or inactivation)

A private well reads a positive coliform result against zero; the coliform-positive well guide covers the retest.

What are the EPA limits for disinfectants and disinfection byproducts?

Disinfectants carry an MRDL with a goal (MRDLG) beside it; their byproducts carry an ordinary MCL. Values in mg/L from EPA’s NPDWR page.

ContaminantMCLG or MRDLG (mg/L)MCL or MRDL (mg/L)
Chloramines (as Cl2)MRDLG 4MRDL 4.0
Chlorine (as Cl2)MRDLG 4MRDL 4.0
Chlorine dioxide (as ClO2)MRDLG 0.8MRDL 0.8
Bromatezero0.010
Chlorite0.81.0
Haloacetic acids (HAA5)n/a0.060
Total trihalomethanes (TTHMs)n/a0.080

A city-water chlorine taste sits under this table, not under a contaminant MCL; the chlorine and chloramine guide covers which filter media takes each one out.

What are the EPA limits for radionuclides?

EPA prints these in the units a lab uses; the table adds mg/L where one exists.

ContaminantMCLGMCL (EPA unit)MCL (mg/L)
Gross alpha particle activity (excluding radon and uranium)zero15 pCi/Lnot a mass unit
Beta particles and photon emitterszero4 mrem/yearnot a mass unit
Combined radium-226 and radium-228zero5 pCi/Lnot a mass unit
Uraniumzero30 µg/L0.030

Radon has no federal MCL in force; the uranium and radon guide covers what a lab result for either means.

What is the PFAS rule as of 2026?

EPA’s 2024 PFAS rule is the first federal MCL for these compounds. Limits are in parts per trillion (ppt, the same as ng/L) as EPA prints them, plus the mg/L equivalent.

PFASMCL (ppt)MCL (mg/L)Status on EPA’s pages, read November 3, 2026
PFOA4.00.000004Enforceable; compliance April 2029, proposed extension to April 2031
PFOS4.00.000004Enforceable; compliance April 2029, proposed extension to April 2031
PFHxS100.00001Enforceable as written; proposed for rescission
PFNA100.00001Enforceable as written; proposed for rescission
HFPO-DA (GenX)100.00001Enforceable as written; proposed for rescission
Hazard Index (PFHxS, PFNA, HFPO-DA, PFBS mixtures)1 (unitless)not a mass unitProposed for rescission

EPA’s PFAS page gives systems until 2027 to complete initial monitoring, and the compliance-extension page states MCL compliance is due April 2029 under the rule as written.

EPA’s Proposed PFOA and PFOS Compliance Extension Rule would grant two more years, to April 2031; its comment period closed July 20, 2026, after a virtual hearing on July 7, 2026, under docket EPA-HQ-OW-2025-1742. EPA’s Proposed PFAS Rescission Rule would withdraw the limits for PFHxS, PFNA, HFPO-DA and the Hazard Index mixture of those three plus PFBS. Both pages were last updated October 8, 2026 with the rules still proposed.

The 4.0 ppt figures for PFOA and PFOS are not part of either proposal; the PFAS in tap water guide covers what a home filter can do.

What is the lead action level?

TriggerLevelIn force
Current lead action level0.015 mg/L (15 ppb), 90th percentile of sampled tapsNow
Lead and Copper Rule Improvements (LCRI) action level0.010 mg/L (10 ppb), 90th percentile of sampled tapsNovember 1, 2027

EPA’s NPDWR page states it directly: beginning on the LCRI compliance date of November 1, 2027, systems must comply with the revised lead action level of 0.010 mg/L. An action level is a system-wide trigger, so one kitchen sample above 0.015 mg/L does not by itself put a utility out of compliance. The lead guide covers the service-line check.

What are the EPA secondary standards?

EPA describes its 15 secondary standards as non-mandatory guides for taste, color and odor, with one exception on the same page: a community system over the fluoride secondary standard of 2.0 mg/L must notify the people it serves within 12 months.

ParameterSecondary standardOwnerSpec guide
Aluminum0.05 to 0.2 mg/Lnone
Chloride250 mg/Lnone
Color15 color unitstannins and tea-colored water
Copper1.0 mg/Lblue-green stains and low pH
CorrosivityNon-corrosiveblue-green stains and low pH
Fluoride2.0 mg/Lfluoride in tap water
Foaming agents0.5 mg/Lnone
Iron0.3 mg/Liron in well water
Manganese0.05 mg/Lmanganese black stains
Odor3 threshold odor number (TON)rotten egg smell
pH6.5 to 8.5blue-green stains and low pH
Silver0.1 mg/Lnone
Sulfate250 mg/Lnone
Total dissolved solids (TDS)500 mg/LTDS meter reading
Zinc5 mg/Lnone

Copper and fluoride appear in both tables: copper 1.3 mg/L primary against 1.0 mg/L secondary, fluoride 4.0 mg/L primary against 2.0 mg/L secondary. The lower figure is the taste and staining guide, the higher one the enforceable limit. Hardness is on neither list; the hard water guide covers the gpg scale, and the TDS meter guide explains why a 500 mg/L TDS reading says nothing about which contaminant is present.

Before you buy anything

Do not buy a filter off this table. A limit tells you what a result means, not what is in your water. Get a certified lab result first, compare each line against the MCL column, then follow the linked guide for the one that is over. If nothing exceeds an MCL and the complaint is taste or staining, read the secondary table.

What should you do first?

  1. Convert the report to mg/L before comparing: 1 ppm equals 1 mg/L, 1 ppb and 1 µg/L each equal 0.001 mg/L.
  2. Mark every result above its MCL or action level in the primary tables; those are the enforceable ones.
  3. Mark every result above a secondary standard separately; those explain taste, stain and odor, not compliance.
  4. For lead, note whether the sample was first-draw or flushed; a single tap result is not the 90th-percentile figure.
  5. Open the linked guide for each marked line; where none is linked, ask your state drinking water program.

What owners buy for this

The top picks from Best water test kit for well and city water: strips vs mail-in certified lab, by published spec, compared on published specs and certifications.

  1. Ten-minute screen before or between lab tests

    Watersafe Drinking Water Test

    10 parameters; lead strip rated to 5 ppb; bacteria vial to 1 bacteria/mL in 6 to 48 hours; made in the USA

  2. Tracking hardness, pH and chlorine weekly on a softener or filter

    Varify 17-in-1 Complete Drinking Water Test Kit

    100 strips, 17 pads incl. hardness, pH, chlorine, iron, copper, fluoride; 2 bacteria vials; no accreditation, no published detection range

See the full comparison and who should skip each one

Frequently asked questions

What is the EPA limit for lead in drinking water?

Lead has no MCL. EPA's National Primary Drinking Water Regulations set an MCLG of zero and a treatment-technique action level of 0.015 mg/L (15 ppb, equal to 15 µg/L) at the 90th percentile of sampled taps. The same EPA page states that from the Lead and Copper Rule Improvements compliance date of November 1, 2027, systems must meet a revised action level of 0.010 mg/L (10 ppb).

What is the EPA limit for PFOA and PFOS in drinking water?

EPA's 2024 PFAS National Primary Drinking Water Regulation sets an enforceable MCL of 4.0 parts per trillion, also written as 4.0 ng/L, for PFOA and for PFOS individually, which is 0.000004 mg/L. EPA's PFAS page gives public water systems until 2027 to finish initial monitoring, with MCL compliance due April 2029 under the rule as written.

Is the EPA PFAS rule still in effect in 2026?

Yes, as written, with two proposals pending. EPA's compliance-extension page proposes moving the PFOA and PFOS deadline from April 2029 to April 2031, and its rescission page proposes withdrawing the limits for PFHxS, PFNA, HFPO-DA and the Hazard Index mixture. Both comment periods closed July 20, 2026, and neither EPA page showed a final rule when read on November 3, 2026.

What is the EPA nitrate limit for well water?

EPA's National Primary Drinking Water Regulations set the nitrate MCL and MCLG at 10 mg/L measured as nitrogen, and nitrite at 1 mg/L as nitrogen. The limit applies to public water systems only; a private well is not regulated, so a well owner compares a lab result against 10 mg/L as N by choice. A report in mg/L as nitrate uses a different scale, so check the unit line first.

What is the difference between a primary and a secondary drinking water standard?

A primary standard is an enforceable MCL or treatment technique in EPA's National Primary Drinking Water Regulations, set for a health-based reason. A secondary standard is one of the 15 non-mandatory levels in EPA's National Secondary Drinking Water Standards, which EPA says guide systems on aesthetic effects such as taste, color and odor. Iron at 0.3 mg/L and TDS at 500 mg/L are secondary; arsenic at 0.010 mg/L is primary.

Fact sheet and how to cite this page

Answer
EPA’s National Primary Drinking Water Regulations set enforceable MCLs for 16 inorganic chemicals, 53 organic chemicals, 4 disinfection byproducts and 4 radionuclide categories, including arsenic 0.010 mg/L, nitrate 10 mg/L and fluoride 4.0 mg/L. The 2024 PFAS rule sets 4.0 ppt each for PFOA and PFOS, and the lead action level is 0.015 mg/L now and 0.010 mg/L from November 1, 2027. Secondary standards such as iron 0.3 mg/L and TDS 500 mg/L are non-mandatory.
Basis
EPA National Primary Drinking Water Regulations (MCLs, MCLGs, MRDLs and treatment-technique action levels), the 2024 PFAS NPDWR, and EPA’s National Secondary Drinking Water Standards.
Assumptions
  • Figures are the federal limits for public water systems; a state may set a stricter limit and a private well is not covered by any of them
  • PFOA and PFOS compliance extension and the rescission of four other PFAS limits were both still proposed rules on EPA’s pages, last updated October 8, 2026, when this page was re-checked on November 3, 2026
  • Lead and copper are treatment-technique rules with a 90th-percentile action level, not an MCL measured at every tap
Method
Every figure copied from the five EPA pages listed under Sources on 2026-11-03, converted to mg/L where EPA prints µg/L or ppt; nothing was tested and no figure comes from a filter maker.
Primary source
EPA, National Primary Drinking Water Regulations (government or regulatory source)
Facts verified
Last updated
Cite as
OwnerSpec, "EPA drinking water standards table: every MCL, MCLG, action level and secondary standard a home water test reports against", https://ownerspec.com/water/guides/epa-drinking-water-limits-table/, facts verified 3 November 2026.

Every figure above also appears, with its source, in the article. All sources · How OwnerSpec verifies numbers

Sources

  1. EPA, National Primary Drinking Water Regulations (government or regulatory source)
  2. EPA, Per- and Polyfluoroalkyl Substances (PFAS) National Primary Drinking Water Regulation (government or regulatory source)
  3. EPA, Proposed PFOA and PFOS Compliance Extension Rule (government or regulatory source)
  4. EPA, Proposed PFAS Rescission Rule (government or regulatory source)
  5. EPA, Secondary Drinking Water Standards: Guidance for Nuisance Chemicals (government or regulatory source)

Found a number that does not match its source? Tell us which page and which figure, and it gets checked against the document and fixed.