Guides

Air equipment guides: a question about a rating, a filter or a deal in, the number that decides it out, with the standard cited by name.

Each guide starts from a rating on a box or a price on a listing and ends at the number that decides whether it fits your room. The standard behind the rating is cited by name.

Thermostats and heat pumps 5 pages

  • Diagnose

    Heat pump blowing cold air: defrost or fault?

    Carrier prints 85–100°F as normal heat pump supply air and a 5–10 minute defrost; Lennox 5–15 minutes every 30–90. Ice over 1/4 inch after defrost is a fault.

    Updated · 8 min read

  • Diagnose

    Aux heat vs emergency heat on a heat pump

    AUX HEAT is automatic backup running with the heat pump; EM HEAT is a manual switch that locks the compressor out. Google says aux costs about 2 to 5 times as much.

    Updated · 8 min read

  • Diagnose

    Thermostat wire colors and terminal letters

    Google Nest Help: R is power, C common, W heat, Y cooling, G fan, O/B heat pump changeover. Colour is a habit: Google prints only blue for C and orange for O/B.

    Updated · 7 min read

  • Diagnose

    Smart thermostat Black Friday deal check: wire first

    A smart thermostat deal is real only if your system is 24 V with a C wire or a maker's power kit, and the exact model number is on the ENERGY STAR list.

    Updated · 8 min read

  • Diagnose

    Smart thermostat C wire: do you need one?

    Google: a C wire only powers the thermostat. Nest, ecobee and Honeywell work on 24 V systems without one via a spare wire or a Y/G adapter. 120 or 240 V means no.

    Updated · 8 min read

Space heaters 4 pages

Air purifiers 4 pages

  • Diagnose

    How often to replace an air purifier filter

    Levoit Core 300 every 6 to 8 months, Coway and Winix HEPA 12 months, Blueair 6 to 9, Honeywell HEPA 12 and pre-filter 3, Shark up to 5 years. Timer vs sensor.

    Updated · 7 min read

  • Diagnose

    True HEPA vs HEPA-type: what each label means

    DOE defines HEPA as 99.97% at 0.3 micrometres; EN 1822 H13 is 99.95% at MPPS. 'HEPA-type' and '99% HEPA' have no standard. How to read the box.

    Updated · 7 min read

  • Diagnose

    Does my air purifier make ozone? CARB list check

    Look the model up on CARB's list: Mechanical means no ozone or ions; Electronic means tested at or below 0.050 ppm. EPA names ionizers, ESPs, plasma and uncoated UV.

    Updated · 8 min read

  • Diagnose

    Air purifier Black Friday deal check: CADR first

    An air purifier deal is real only if its smoke CADR is at least two-thirds of the room's square feet (AHAM). The box room size is the 1-air-change figure.

    Updated · 8 min read

Humidifiers 3 pages

Furnace filters 3 pages

  • Diagnose

    Furnace filter arrow direction: which way it points

    The furnace filter arrow points toward the blower, the way air flows: up in an upflow, down in a downflow, into the wall at a return grille (Trane, Carrier, Lennox).

    Updated · 6 min read

  • Diagnose

    MERV vs MPR vs FPR: what each filter rating means

    MERV comes from ASHRAE 52.2 tests of 0.3 to 10 um particles in three ranges; MPR is 3M's 0.3 to 1 um scale; FPR has no standard. No conversion exists.

    Updated · 9 min read

  • Diagnose

    How often to change a furnace filter, by depth

    A 1-inch furnace filter is changed every 30 to 90 days (Carrier, Trane, ENERGY STAR); a 4- or 5-inch media filter every 6 to 12 months (Honeywell, AprilAire).

    Updated · 8 min read

Smoke and CO alarms 2 pages

  • Diagnose

    Smoke detector chirping: battery or end of life?

    Chirping every hour? No manual prints that: 1 chirp every 30-60 s is a low battery. Still chirping with a new battery means a stale error or end of life.

    Updated · 11 min read

  • Diagnose

    Carbon monoxide detector beeping: what it means

    Four beeps is a CO alarm on Kidde, First Alert and X-Sense units: get to fresh air and call 911. One chirp a minute is low battery; 2 to 5 a minute is end of life.

    Updated · 8 min read

Radon 2 pages

  • Diagnose

    Radon manometer U-tube reading: what it means

    The U-tube shows suction in inches of water column, never radon. Even levels mean the fan stopped. Compare to the installer's sticker and retest every 2 years.

    Updated · 7 min read

  • Diagnose

    Radon level in pCi/L: what the number means

    EPA says fix the home at 4 pCi/L (150 Bq/m3) and consider fixing between 2 and 4 pCi/L; WHO's reference level is 100 Bq/m3. One short-term result is not the verdict.

    Updated · 8 min read

Air quality monitors 1 pages

Dehumidifiers 1 pages

  • Diagnose

    Humidifier vs dehumidifier: which do I need?

    EPA says keep indoor RH below 60%, ideally 30 to 50%. Under 30% in winter means a humidifier, above 60% means a dehumidifier, and 30 to 50% means neither.